DIVATECH D
INSTANT COMBI WALL HUNG GAS BOILER
THE RANGE
Five models for heating and for production of domestic hot water
model C24
NATURAL DRAUGHT, OPEN FLUE - THERMAL OUTPUT 23.5 kw - DHW 13.4 l/min at ∆t 25°C
model F24
forced flue, room sealed - THERMAL OUTPUT 24 kw - DHW 13.7 l/min at ∆t 25°C
model C32
NATURAL DRAUGHT, OPEN FLUE - THERMAL OUTPUT 31.3 kw - DHW 17.9 l/min at ∆t 25°C
model F32
forced flue, room sealed - THERMAL OUTPUT 32 kw - DHW 18.3 l/min at ∆t 25°C
model F37
forced flue, room sealed - THERMAL OUTPUT 37 kw - DHW 21.1 l/min at ∆t 25°C
2 models for heating only
model HF24
forced flue, room sealed - THERMAL OUTPUT 24 kw
model HF32
forced flue, room sealed - THERMAL OUTPUT 32 kw
-
Technical Data
- Primary heat exchanger with compact geometry made entirely of copper
- Instantaneous production of domestic hot water with dedicated plates exchanger
- Simple and complete revamped control panel, user interface with display and setting keys
- Circulator with 3 levels di flow rate/head pressure with anti-blocking system that is activated for a few seconds every 24 hours of inactivity
- New hydraulic group specifically designed to allow quick and easy maintenance by the installer
- The domestic water inlet filter can be easily extracted from the inside without having to remove the hydraulic connections of the boiler
- The disassembly and replacement of the plate exchanger, if required, can only take place by removing two Allen bolts that can be accessed from the front
- Compact size and contained weight
- Sliding temperature operating mode through external probe (optional)
- Can be combined with the modulating remote control timer (optional)
- Modulatingthermal flow during both heating and production of DWH, managed by a microprocessor electronic card
- ECO/COMFORT system for fast production of DWH
- Preset for solar energy system: pre-set for production of domestic hot water combined with solar panel systems (SUN EASY)
- E.C.S. Innovative combustion control that ensures optimal operation at various heat load and chimney conditions
-
Manuals
-
Depliant
-
Certifications